DONGGUAN LONROY EQUIPMENT CO LTD

Manufacturer from China
Verified Supplier
1 Years
Home / Products / Lab Test Machine /

Elevated Temperature Vacuum Rubbing Wear Testing Machine

Contact Now
DONGGUAN LONROY EQUIPMENT CO LTD
Visit Website
City:dongguan
Province/State:guangdong
Country/Region:china
Contact Person:MsKaitlyn Wang
Contact Now

Elevated Temperature Vacuum Rubbing Wear Testing Machine

Ask Latest Price
Video Channel
Brand Name :Lonroy
Model Number :LR-MUG
Certification :CE ASTM ISO
Place of Origin :China
MOQ :1
Price :Negotaible
Payment Terms :D/A,D/P,T/T,Western Union,MoneyGram,L/C
Supply Ability :200
Delivery Time :5-8 work days
Packaging Details :wooden package
Friction force measurement range :1-300N
Rotational speed control accuracy :±1r/min
Temperature measurement accuracy :±2℃
Relative error of test force indication :±1%
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Elevated Temperature Vacuum Rubbing Wear Testing Device

Product Introduction

The LR-MUG type surface processing performance tester is a product developed and improved by our company. It adopts the forms of disc, ball disc and end face sliding friction, and can conduct tests under various conditions such as room temperature or high/low temperatures, vacuum, multiple atmospheres, changing lubrication states (oil-free lubrication or oil immersion lubrication), load, speed, friction mate materials, surface roughness of the friction pair, hardness, etc., by applying a relatively high end face test force to the ring-shaped sample. It is mainly used to evaluate the friction performance of engineering materials, powder metallurgy, alloy bearings and other materials under different conditions, and can be applied to the selection of friction pair materials and the research on the anti-wear performance of materials.

Product Parameter

Test force working range

10 - 5000 N (stepless adjustable, programmable control during operation)

Relative error of test force indication

±1%

Friction force measurement range

1-300N

Relative error of friction force indication

±3%

Main shaft rotational speed range

1 - 2000 r/min (process control)

Rotational speed control accuracy

±1r/min

High temperature control range

Room temperature ~ 1200

Low temperature control range

Room temperature ~ -25

Temperature measurement accuracy

±2

Inquiry Cart 0