Brand Name :LONROY
Place of Origin :Guangdong, China
MOQ :1
Accuracy :±0.5%
Protection Class :IP56
Voltage :220 V
Temperature Precision :0.1℃
Battery Voltage :1.5 volts
Measured Surface Diameter :50mm
Temperature Measurement Range :-80℃ to 100℃
Temperature Accuracy :±0.5%
Operating Temperature :0 - 50℃
Operating Humidity :≤85%
Dew Point Range :-60℃ to -40℃
Contact Time :Standard determined
Test Surface Diameter :50mm
Cooling Method :Dry ice
Temperature Increment :5℃
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Insulating Glass Dew Point Performance Test Instrument Insulated Glass Dew Point Meter Hollow Glass Dew Point Detector

Product Description


Introduction
The dew point meter is designed and manufactured in accordance with the national standard GB/T11944-2012 "Insulated Glass". It is a specialized instrument used for detecting the dew point performance of insulating glass.
The dew point meter consists of a copper base glass tube and a dedicated low-temperature digital thermometer.

Usage instructions
1. Inject approximately 25mm of ethanol into the glass tube. Turn on the thermometer switch, insert the probe into the glass tube, add dry ice to lower the temperature to ≤ -60℃, and maintain the temperature at -60℃ throughout all the tests by adding dry ice to the glass tube.
2. Place the sample horizontally, apply a layer of ethanol on the upper surface, ensure that the dew point meter is in close contact with this surface, and the contact time should be determined according to the standard requirements.
3. Remove the dew point meter, immediately observe whether there is condensation or frost on the inner surface of the glass sample. If there is no frost or condensation, record the dew point temperature as -60℃. If there is condensation or frost, place the sample until there is no frost or condensation, then increase the temperature of the dew point meter and continue the measurement, increasing the temperature by 5℃ each time until -40℃ is reached. Record the highest condensation temperature of the sample, which is the dew point temperature of the sample.



Insulating Glass Dew Point Performance Test Instrument Insulated Glass Dew Point Meter Hollow Glass Dew Point Detector

Technical Specification

Measured Surface Parameter

Measured surface diameter: 50mm

Temperature Measurement

Temperature measurement range: -80℃ to 100℃; Accuracy: ±0.5%

Temperature Precision

Precision: 0.1℃

Battery Specification

Battery voltage: 1.5 volts

Operating Environment

Temperature: 0 - 50℃; Relative humidity: ≤85% (without corrosive gases)

Equipment Inclusion

1× High-precision digital thermometer, 1× Glass tube, 1× Copper base, 1× Certificate of conformity, 1× User manual, 1× Dry ice production device